Instructions and manuals for the operation of Mercury electric meters. Instructions and manuals for the use of electricity meters mercury Mercury 230 art instruction manual

The Mercury 230 counter can be used with equal success in everyday life and for industrial purposes. This device is a frequent guest in luxury cottages containing a large number of various electronics, from refrigerators, washing machines and ending with underfloor heating.

You may also be interested in what methods of transmitting electricity readings exist. And if the resulting numbers are too large, you should think about saving, which you can read about.

There is a special modification for transformers that can work autonomously or in conjunction with an automated electricity consumption control system.

Design description

The Mercury 230 direct-flow meter works on the same principle as other devices of this kind: it receives signals from special sensors and translates them into the language of power and energy.

The user can, at will, read the data both directly from the device itself and remotely.

The design of the device includes the following elements:

  • frame;
  • measuring device;
  • terminal block and cover.

Current transformers and resistive dividers are the first to pick up incoming signals. Then the information is received and converted into a digital code by the microprocessor. Thanks to this, the equivalent of the consumed power is displayed. Another function of the processor is to control the electrical units of the meter.

Specifications

It does not make sense to list the characteristics of the model in full, since it will take a lot of time. It is worth noting especially important parameters:

  1. Accuracy class. This indicator determines the percentage of instrument error. The larger it is, the less reliable the mechanism is considered. The Mercury 230 electric energy meter has an accuracy class of 0.5, which is an excellent indicator.
  2. Rated voltage - 3 * 57.7 per 100 V. Maximum current - 5 A.
  3. Dimensions - 258 by 170 by 74, weight does not exceed 1.5 kg.
  4. Operating temperature - almost any, from -40 to +55 Celsius.
  5. Additional features. The device has burglary protection, there is a seal on the front panel. The meter can diagnose its own problems and generate an error.

Many technical characteristics (rated voltage, max current, etc.) depend on the specific model. Description Mercury 230 differs markedly from simpler models.

Basic and advanced features

The set of functions also depends on the chosen modification (see below). In this case, the list of basic and additional functions is given in the form that is typical for Mercury 230 ART models:

Modifications

Descriptions of Mercury 230 meters would not be complete without mentioning modifications. The series is distinguished by a large number of modifications, as different areas of application require additional functionality. It is not possible to fit them into one model. Yes, and the cost of such a device will be exorbitant.

Here are some model modifications:

  1. Mercury 230 AM. The device offers accounting in a single tariff mode, assuming only an increase in data from the moment the device is put into operation. The device can be used offline and in the ASKUE system.
  2. Mercury 230 AR. The model offers consumption accounting for a separate phase or as a whole. The meter "cooperates" with CAN, RS - 481 interfaces. Another advantage of the model is a programmable phase summation mode, which will prevent cases of electricity theft.
  3. Mercury 230 ART. In this case, there are several modifications, among them is the Mercury 230 ART 01 electric meter. It is distinguished by a wide range of additional functions that will allow you to buy what the user specifically needs.

The three-phase counter Mercury 230 is a device of new release. This device has telemetry outputs and a special interface designed for information exchange. An electronic seal is installed on the device, the device can carry out automatic diagnostics of various malfunctions. The manufacturer of electric meters is the company "NPK Incotex".

Device Description

A direct-flow meter Mercury 230 is installed to account for electricity in three-wire and four-wire networks. The device can be connected either by direct or transformer method. If a transformer is connected to the device, then it will be possible to take into account electricity at objects with a high load.

The device, which has three phases, has a liquid crystal display. This screen displays data in kilowatt-hours. The display has 8 digits. The first 6 digits show integer values ​​of kWh, the last 2 - decimal places, hundredths of kWh. The error that exists in the readings of this device is 1.0. Devices are installed indoors, where the air temperature can be -40 ... + 55ºC.

If the device is connected through a transformer, then it is possible to measure a current greater than that for which the device is calculated. Counters are mounted in the domestic and industrial sectors. Household appliances are installed in residential buildings. Industrial appliances are used in the industrial sector, in businesses, factories and plants. Counters are induction and electronic. Electronic ones have a high quality certificate, are more accurate, they do not have rotating parts and convert the signal that comes from the measuring elements.

Specifications

The electronic counter Mercury 230 differs in the increased accuracy and high reliability. The smallest operating time is 150 thousand hours. Duration of operation of the device - 30 years. The terms of verification of electric meters (inter-verification interval) are 10 years. The warranty period is 3 years from the date of manufacture.

Specifications:

  1. The rated current for the transformer connection is 5 A.
  2. The base current for direct connection of the device is 5 A or 10 A.
  3. The highest current strength is 60 A.
  4. The phase voltage indicator is 230 V.
  5. Frequency -- 50 Hz.
  6. 2 pulse output modes: basic, verification.
  7. The limit of permissible error of the device refers to accuracy class 1.
  8. Dimensions, dimensions: 258x170x74 mm.

When there is no current in the series circuit, the instrument's test output, when measuring active and reactive energy, does not generate more than one pulse per 10 minutes. These devices are highly durable and reliable. Previously, they were installed at manufacturing enterprises. Now they are often used when wiring electricity in country houses. This is due to the presence of a large number of household appliances, which require a high power supply.

Basic and advanced features

Now electric meters, in addition to the main function - electricity metering, have various additional properties, with the help of which it is permissible to control some of the characteristics of the electrical network and the modes of the device itself. You can take data from this device not only at the place of operation, but also remotely through some types of interface. The Mercury two-tariff meter is a device that has enhanced capabilities.

Standard connection options for a three-phase meter Mercury 230:

  1. Measurement of electricity data, their storage and visualization on the display for such a time interval: from the last reset, 24 hours, 30 days, a year.
  2. The device can take into account the current according to two tariff plans for 16 time zones.
  3. The device can be programmed every month for a new tariff.

The device records the following characteristics:

  • instant power calculation;
  • determination of potential difference;
  • definition of current by phases;
  • network frequency indicator;
  • power in different phases and total.

The device has maximum protection. If the limit is exceeded, the device notes this, the exact time when the excess occurred is also indicated. The digital output allows you to control the load.

The machine has an event log. It contains the following indicators:

  • the time of connecting the device to the network and disconnecting from it;
  • phase accounting;
  • adjustment of the tariff schedule;
  • accounting for the opening of the counter;
  • exceeding the limit.

Consider additional features of the device. The counter has additional functions:

  • electricity metering in forward and reverse directions;
  • it is possible to transfer data on the consumption of electricity for each phase;
  • the presence of an archive of power data with an interval of 1 to 45 minutes;
  • the archive data storage period is 85 days;
  • the highest indicator of morning and evening power;
  • accounting for losses;
  • accounting for magnetic impact with data recording in a special journal;
  • power quality control.

Wiring diagram

Consider how to connect the device. You can connect the meter according to different schemes, in which current transformers will be used as a data source. Here is a connection diagram for the Mercury 230 meter. The most common is a ten-wire connection diagram for the device. Its advantage is the presence of power circuits and measuring instruments. The disadvantage is a large number of wires.

The sequence of connecting the meter and transformer:

  • terminal 1 - input A;
  • terminal 2 - input of the end of the measuring winding A;
  • terminal 3 - output A;
  • terminal 4 - input B;
  • terminal 5 -- input of the end of the measurement winding B;
  • terminal 6 -- output B;
  • terminal 7 -- input C;
  • terminal 8 -- winding termination input C;
  • terminal 9 -- output C;
  • terminal 10 -- zero phase input;
  • terminal 11 -- zero phase on the voltage side.

To install the meter in a break in the transformer circuit, terminals L1 and L2 are used. You can connect the meter using a semi-indirect circuit. In this case, the current transformers are connected to a star. Then the installation of the device is facilitated and less wires are needed. The accuracy and quality of the data does not deteriorate.

A seven-wire method for connecting a TT is also used. Its disadvantage is the lack of galvanic isolation of circuits. Such a scheme is considered dangerous to use and is now almost never used.

Connecting an electric meter Mercury 230 has much in common with installing a single-phase device. But there are many differences in the installation of the installation. The connection diagram is available on the meter body, on the reverse side of the cover.

During installation, the color sequence must be observed. Even numbers of wires correspond to the load, odd numbers - to the input. Three-phase multi-tariff meter connection schemes are used.

When the meter is connected to three-phase consumers, the process is carried out through current transformers. This scheme makes it possible to reduce the cost of electricity and increase the reliability of its supply. Direct-on meters do not exceed 100 A. This is due to the limitation of the conductor dimensions. The higher the current, the larger the cross section of the wire is needed to pass it. Such limitations are eliminated by current transformers.

Consider the connection diagram of the meter through the test terminal box: the terminals in the block are designated by the letters A, B, C. A wire comes to these terminals, which is connected to the 380 V power buses, and then goes to the meter through jumpers.

If necessary, the jumpers are untwisted, shifted, and the chain is broken. This can remove the mains voltage and ensure the safe operation of the device connected to the test box. ICC has a protective cover and a sealing device, a screw with a hole. The installation of the seal is carried out together with the installation of the meter.

Consider how to take readings of the electricity meter. The device has a 6-digit dial. It is necessary to write out all the numbers up to the decimal point. To calculate the energy consumption for the month, it is necessary to subtract from the new readings those that were last month.

Let's find out how to take readings from a multi-tariff meter (article Mercury 230 ART-01). To do this, you need to write down the following data: T1 - current consumption during the day, T2 - current consumption at night. Before writing data, you need to make sure that the machine is in the ready mode.

There should be a line near mark A. If not, then press the right button. Then press the Enter button. In this case, the display will show the current consumption data for the day T1. Press Enter a second time and overwrite the value of T2 (at night).

Modifications

There are such modifications of Mercury counters:

  1. Single tariff three-phase, multi-tariff and multifunctional: Mercury 230 ART, Mercury 231 AT.
  2. Three-phase active and reactive electrical energy single tariff, article: Mercury 230 AR.
  3. Three-phase active energy single tariff: Mercury 230 AM, Mercury 231 AM.
  4. Single-phase active energy, single-tariff and multi-tariff: Mercury 200, Mercury 202, Mercury 201.

The SIKON controller is installed in Mercury meters with active and reactive energy with an internal rater, the devices can be bidirectional or unidirectional.

The energy that is used to feed electrical appliances and various kinds of equipment, as you know, is rapidly becoming more expensive and requires accounting and control of consumption. For this purpose, energy metering devices - electric meters - are installed in the premises.

This article will discuss the benefits of using and characteristics of the Mercury 230 ART 03 meter. However, before proceeding with the analysis of this equipment, some points should be clarified.

Which counter to choose

A single-phase electricity meter is installed in a two-wire network with alternating current and a voltage of 220 volts. Three-phase controls consumption and takes into account electricity, however, it works on the basis of three-wire (and four-wire) networks with a frequency of 50 Hz, with alternating current and a voltage of 380 volts.

A much more complex apparatus is a three-phase meter. It is installed to control the energy consumption in industrial buildings, factories, factories and other enterprises where a large amount of electricity is consumed.

If there is no neutral wire in the building, a three-wire meter should be taken; if there is a neutral wire, a four-wire meter should be used.

Three-phase measuring instruments of the Russian company "Mercury" are produced by the well-known company "NKP" Incotex. Among 120 varieties, there are both simple single-phase and the most complex multi-tariff devices, with the ability to control the load and transmit measurements to remote devices.

Some analogues of modifications Mercury 230 ART - 03

  • Mercury 230 ART -00 PQRSIDN - Mercury 234 ART -00 P;
  • Mercury 230 ART -01 PQRSIN - Mercury 234 ART -01 P;
  • Mercury 230 ART -02 PQRSIN - Mercury 234 ART -02 P;
  • Mercury 230 ART-03 PQRSIDN - Mercury 234 ART-03 P.

Electric multi-tariff unidirectional electronic active-reactive electricity transformer connection Mercury 230 ART -03 CN (R) (230 ART -03 CN - CAN communication interface; 230 ART -03 RN - RS-485 communication interface)

  • Mercury 230 AR-01 CL;
  • Mercury 230 AR -02 CL;
  • Mercury 230 ART-01 CLN;
  • Mercury 230 ART -02 CLN.

Three-phase counter Mercury 230 single tariff

One of the most uncomplicated devices can be called a single-tariff three-phase meter Mercury 230. Such an electrical meter is offered for operation by users who have three- or four-wire AC networks.

It works well in tandem with equipment designed for automatic regulation of electricity. The 230 ART 03 series meter is one of the metering devices for electricity consumption in AC networks. It is used both for economy and convenience.

The functioning of electric meters is based on the transformation of signals from devices for fixing current and voltage into numbers on a liquid crystal screen. Data from such devices can be taken both in direct contact and at a distance using built-in programs.

Application of the counter Mercury 230

Mercury 230 ART 03 is used both in industry and production, and in everyday life. It can be found in private houses and dachas, where electrical appliances operate that consume large amounts of energy, such as boiler rooms, floor heating, outdoor lighting and other energy-volume systems that consume this resource.

Additional tasks

In addition to electricity metering, this device performs many additional configurations, including accounting and storing data on the electricity used for a specific time period, taking into account the tariff schedule in a multi-tariff mode.

Activating a multi-tariff or two-tariff mode guarantees savings by using different tariffs for 24 hours. It is not always necessary to use tariff 4; for domestic needs, it is enough to install a two-tariff electricity meter.

The design of the electricity meter

Elements of the structure of the device:

  1. Frame.
  2. Contact block.
  3. Protective cover.
  4. Measurement and indication device.

Device Features

This resource metering tool is able to process data at four rates simultaneously, which allows you to save electricity costs at night. The device is equipped with a liquid crystal screen that displays large numbers and therefore will be convenient to use for people with poor eyesight.

The reliability of the accounting tool is evidenced by the period of its application - it is 30 years. Verification interval - 10 years from the date of the previous verification. It is possible to take into account the active energy of the direct direction separately in each phase of the network.

The device functions smoothly at low and at high temperatures. The temperature range of application of the device from -40 to +55, allows you to use it in the most whimsical and unpredictable conditions, which makes the device multidirectional.

The device allows you to inspect various types of readings, keep records of active and reactive energy of the direct direction for different time periods, fix the voltage in all phases of the network, set the level of active, reactive and apparent power, control power factors, network frequency and much more.

The presence of an electronic seal will protect the device from misuse, with the aim of stealing electricity by unauthorized people.

Instructions for setting up the counter Mercury-230-03

The equipment is configured using the “Configurator” program through the CAN-RS232 converter or an optical port, if the device has one.

First you need to set the last three digits of the device number, click "test connection" to check the connection, and receive a notification about the quality of the connection on the equipment screen itself.

Any device that has caught the request will respond to a network address equal to zero.

After the data exchange has been successfully completed, it is necessary to familiarize yourself with the important characteristics of the device - parameters and settings. Entering the second level password in the "connection parameters" window, select the "open" function.

If the device has not been turned on before, set the time and seasonal change on the meter, initialize the power profile and set the integration time for half an hour, then wait for some time, allow the program to complete the profile initialization.

When reading the power profile (“show” button), you must specify the date and time interval for which data is needed. Following this, you need to set the password for the first access level and check the opening of the communication channel. If the attempt is unsuccessful, the first level password must be obtained from the owner of the equipment.

Additional data provided by the meter

In addition to the above data, you can get momentary values ​​of the phase powers, each separately and their sum, data on the direction of the total power vector.

You can request the effective values ​​of phase currents and voltages, network frequencies, power factors for each phase and for the total sum of the phases.

The meter has the ability to set active power limits and turn off the consumed object in case of violation of the norms of the resource reception limit.

Instrument verification and maintenance

According to the instructions, the verification of the meter once every 8 years is carried out by the bodies of the State Metrological Service or accredited metrological services of legal entities.

Maintenance work is carried out by employees of the company that operates the meters. Previously, the above-mentioned employees must study the manual for using the device and undergo safety training, these persons must have a safety qualification of at least III.

The warranty period of the meter, according to the instructions, is 36 months from the date of putting the meter into operation.

Error e01 on the counter

No matter how high-quality the technique is, it is exposed to contact with external objects and phenomena that can adversely affect its condition and quality of work. In case of failure or emergency situations, an error code in the format “E-xx” appears on the indicator. Among the errors are memory malfunction, power limit, and so on.

Error E-01 occurs when the battery voltage is less than 2.2. To fix it, it is recommended to replace the battery.

Conclusion

The Mercury meter has exceptional data accuracy, does not require high power supply, its calibration interval is 10 years, it is possible to save money according to the tariff schedule, the device has an impressive list of programs that make it possible to manage and control the device's actions. In other words, the device combines the parameters of quality factor, durability, multitasking and acceptable cost.

Product in stock!

Terms of ordering and delivery of adapters for communication with Mercury meters
(e-mail requests [email protected] or call 8-909-283-34-16)


1) The cost is 6000 rubles. Buy. Miniature USPD for querying lists of Mercury counters via any of the connected USB-RS485/CAN/IRDA/optoport interfaces. It can independently interrogate 10 three-phase Mercury meters, or create an end-to-end tunnel through itself for polling an unlimited list of meters by external programs.

2) Ethernet-RS485 (VR-008.1) The cost is 3600 rubles. Buy. A complete hardware device for data transmission between an Ethernet local area network and a wired RS485 interface. It is widely used to automate the taking of readings from metering devices, including Mercury electricity meters. Works with all kinds of TCP/IP protocols in server and client modes. It can be displayed on the Internet for remote monitoring of ASKUE accounting objects.

3) USB-IRDA (Model VR-001) The cost is 1950 rubles. Buy. Interface converter for electricity meters Mercury-230, 231, SE-102 containing IRDA interfaces. To connect to the electric meter does not require opening the terminal box.

4) USB-RS485/CAN (Model VR-002) The cost is 1950 rubles. Buy. Universal converter of wire interfaces RS485/CAN. Can supply power to the electricity meter interface. Suitable for Mercury-200, 203.2T, 206, 230, 233, 234, 236 containing RS485/CAN. Connection requires opening the terminal box. It is possible to connect highways with meters.

5) USB-RS485 (Model VR-004) The cost is 850 rubles. Buy. Suitable for Mercury meters that do not need to power the communication interface. It has output terminals D+ and D- only. Can be used with Mercury-203.2T, 206, 230, 233, 234, 236 containing RS485. Requires opening the terminal box for connection.

6) USB optoport (model VR-005) The cost is 1950 rubles. Buy. Suitable for electricity meters Mercury-201.8TLO, 203.2T, 206, 233, 234, 236 containing optoport. Connection does not require opening the terminal box.

8) JTT-A (RS485/CAN) (radio modem 433 MHz, 100 mW) The cost is 4000 rubles. Buy. Miniature radio modems with a transparent communication channel that allow you to work with electricity meters in the radio extender mode. They have the ability to connect to industrial RS485/CAN interfaces and allow you to create group or single electricity metering units in hard-to-reach places.

9) Automation unit - WiFi router (model VR-007.3) The cost is 5000 rubles. Buy. A smart home element that allows you to conduct an automated poll of a three-phase Mercury meter through any of the connected USB-RS485 / CAN / IRDA / optoport interfaces. It has its own adaptable Web interface, database, can poll instantaneous values ​​of currents, voltages, powers every minute, build energy graphs by month and day. It has the ability to broadcast a webcam and weather stations through itself, it is an element of a smart home capable of transmitting consumption data to the user's e-mail and to sales. It can output data to the Narodmon.ru server and report critical situations.




Delivery (added to the cost of the goods):

1) Russian Post - first class registered parcel. The price is 300 rubles. Delivery time 3-5 working days. A tracker is issued.

To take readings from the counter, we write down all the numbers up to a comma or point.

Electricity meters of the Mercury 230 model (three-phase) may differ from each other. According to the number of tariffs, there are single-tariff and multi-tariff models (two-tariff, three-tariff) of the type day-night and peak semi-peak night.

Specifications

The meter is designed to account for active electricity. The measurement accuracy class of the device, regardless of the model, is 0.5 or 1. Manufacturers give a 3-year warranty on the counter. As a rule, the service life of electricity meters is about 30 years. The calibration interval for Mercury 230 is 10 years. That is, every ten years it is necessary to check the meter to detect malfunctions in the account, if any.

Consider the removal of indicators using the example of a three-phase electric energy meter of a single-tariff and two-tariff type.

We remove indicators from a single-tariff counter mercury 230

Popular varieties of single-tariff type electric meters:
Mercury 230 AR/AM1
Mercury 230 AR/AM02
Mercury 230 AR/AM03

In order to record the readings of a single-tariff mercury meter, look at the 6-digit dial and write down the numbers up to the decimal point.

To determine the meter reading for the last month from the current fresh meter reading, subtract the reading that was a month ago.

We take readings from a multi-tariff meter

Popular types of multi-tariff type electric meters:

    Mercury 230 ART-01
    Mercury 230 ART-02
    Mercury 230 ART-03

In order to take and transmit readings from the meter, you will need to record the following indicators
T1 - electricity consumption in the daytime
T2 - electricity consumption at night